Portable System Customisation
The USB-Acc and USB-Vib Personality modules can be badged and labelled to reflect your corporate identity. Simple flash screen and label options through to fully customised applications are supported by the DiagSol development team
|
USB Acc |
|||
|---|---|---|---|
| Size | 30mm A/F x 60mm H | Weight | 130grms |
| Frequency Response | 2Hz – 10kHz | S/N Ratio | 96dB |
| Noise | < 0.001g | Power | USB Host |
| Compatibility | Min 400MHz XScale | Windows Mobile | Windows XP, Vista |
| EPROM Calibration | Stored ref 1g ± 3% | Cross Axis Sensitivity | < 5% |
| Temperature Range | -25 to 80 oC | Data Feed | Streamed Digital (no storage) |
The hand held device will operate as a condition checker OR route mode vibration collector as shown in the following table.
![]() |
USB-Vib Pocket PC Software |
|---|---|
| Frequency Increments (Hz) | 50,100, 200, 500, 1k, 2k, 5k, 10k |
| No of Lines | 100, 200, 400, 800, 1.6k, 3.2k, 6.4k, 12.8k |
| Filter Options | 2Hz HP, 2kHz LP |
| Pre-Demodulation Band Pass Filters |
1kHz-2kHz, 2kHz-4kHz, 4kHz-8kHz |
| Measurement Parameters | Time & frequency domain (g’s, demod g’s and velocity) |
| Symptoms* | Velocity (1x, 2x and ISO 10816) Demodulated g’s (Carpet & Non Synch Energy) |
| Built in Alarms (ISO based) | Sets based on 6 frequency ranges and 7 asset types |
| Navigation | Route based** or meter mode with csv save |
* Symptom set constantly under review and development
** Route based data collection requires SmarTrend or OEM software